{"product_id":"davey-microlene-uv-water-disinfection-system","title":"Davey Microlene UV Water Disinfection System - UV24 to UV250, 23–208 LPM NZ","description":"\u003ch2\u003eDavey Microlene — UV Water Disinfection Systems\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eTreat your water against harmful micro-organisms, without chemicals.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Davey Microlene range covers five standalone UV disinfection systems — from compact units for small households to high-output systems handling up to 208 LPM. These are UV-only units. They do not include filter housings or cartridges. Pre-filtration must be installed upstream of the UV unit — see the pre-filtration section below.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBore water quality varies significantly. We recommend testing your bore water before selecting a UV system — get in touch and we'll help you choose the right configuration for your supply.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003ePre-Filtration\u003c\/h2\u003e\n\n\u003cp\u003eUV works best on clean, particle-free water. Particles in the incoming supply can shield micro-organisms from the UV light, reducing treatment effectiveness. As a minimum, 20 micron cartridge filtration is recommended upstream of the UV unit. Where Giardia or Cryptosporidium are a concern, 1 micron filtration is required at drinking water taps.\u003c\/p\u003e\n\n\u003cp\u003ePre-filtration components are not included with these units and must be set up separately. Get in touch and we'll recommend the right combination for your water supply.\u003c\/p\u003e\n\n\u003ch2\u003eChoose Your Model\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel\u003c\/th\u003e\n      \u003cth\u003eFlow Rate (30 mJ\/cm² @ 95% UVT)\u003c\/th\u003e\n      \u003cth\u003eConnection\u003c\/th\u003e\n      \u003cth\u003eChamber Material\u003c\/th\u003e\n      \u003cth\u003eLamp Life\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV24\u003c\/td\u003e\n      \u003ctd\u003e23 LPM\u003c\/td\u003e\n      \u003ctd\u003e¾\" NPT\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV57\u003c\/td\u003e\n      \u003ctd\u003e57 LPM\u003c\/td\u003e\n      \u003ctd\u003e1\" NPT\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV80\u003c\/td\u003e\n      \u003ctd\u003e79 LPM\u003c\/td\u003e\n      \u003ctd\u003e1\" NPT\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV151\u003c\/td\u003e\n      \u003ctd\u003e151 LPM\u003c\/td\u003e\n      \u003ctd\u003e1½\" NPT\u003c\/td\u003e\n      \u003ctd\u003e316L SS\u003c\/td\u003e\n      \u003ctd\u003e10,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV250\u003c\/td\u003e\n      \u003ctd\u003e208 LPM\u003c\/td\u003e\n      \u003ctd\u003e2\" BSP\u003c\/td\u003e\n      \u003ctd\u003e316 SS\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eAll flow rates shown at 30 mJ\/cm² — the minimum recommended industry standard for drinking water treatment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eConnection note:\u003c\/strong\u003e UV24, UV57, UV80, and UV151 have NPT connections. NPT is not the NZ plumbing standard — your plumber will need BSP-to-NPT adaptors, available from most plumbing merchants. The UV250 has 2\" BSP connections, which are standard.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVoltage note:\u003c\/strong\u003e The UV250 operates on 230–240V\/50Hz only. Confirm this is compatible with your installation before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eHow UV Disinfection Works\u003c\/h2\u003e\n\n\u003cp\u003eThe UV lamp operates at 254nm. As water passes through the stainless steel chamber, the UV light penetrates micro-organisms present in the supply, damaging their ability to reproduce and cause illness. Organisms exposed to UV are no longer viable to cause infection and cannot be detected on a culture plate.\u003c\/p\u003e\n\n\u003cp\u003eUV treatment adds no chemicals and leaves no residuals. It does not change the taste, smell, colour, or chemistry of your water.\u003c\/p\u003e\n\n\u003ch2\u003eFeatures Across the Range\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eAll models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial flow, polished stainless steel chambers\u003c\/li\u003e\n  \u003cli\u003eVisual sight port to confirm the lamp is operating\u003c\/li\u003e\n  \u003cli\u003eTool-free bayonet lamp connector — quarter-turn removal, no tools needed\u003c\/li\u003e\n  \u003cli\u003eFully potted ballast in a splash-proof controller — resists water damage\u003c\/li\u003e\n  \u003cli\u003eAudible and visual lamp failure indicators\u003c\/li\u003e\n  \u003cli\u003eMounting brackets supplied\u003c\/li\u003e\n  \u003cli\u003eDesigned and manufactured to ASME pressure vessel standards\u003c\/li\u003e\n  \u003cli\u003eAll wetted components USFDA listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eUV24 \/ UV57 \/ UV80 \/ UV151 — integral lamp life monitor:\u003c\/strong\u003e\u003cbr\u003e\nThese models include a lamp change reminder. The controller provides both audible and visual advance warning as the lamp approaches end of life — giving you time to arrange a replacement before the lamp fails completely.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eUV250 — alarm on failure:\u003c\/strong\u003e\u003cbr\u003e\nThe UV250 uses a separate power supply enclosure with an orange mains-on indicator and a red visible alarm indicator. The alarm triggers when the lamp fails. There is no advance reminder on this model — replace the lamp annually as a matter of routine, or when the alarm activates.\u003c\/p\u003e\n\n\u003ch2\u003eFull Technical Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eUV24\u003c\/th\u003e\n      \u003cth\u003eUV57\u003c\/th\u003e\n      \u003cth\u003eUV80\u003c\/th\u003e\n      \u003cth\u003eUV151\u003c\/th\u003e\n      \u003cth\u003eUV250\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow — 16 mJ\/cm² @ 95% UVT\u003c\/td\u003e\n      \u003ctd\u003e41 LPM\u003c\/td\u003e\n      \u003ctd\u003e110 LPM\u003c\/td\u003e\n      \u003ctd\u003e150 LPM\u003c\/td\u003e\n      \u003ctd\u003e295 LPM\u003c\/td\u003e\n      \u003ctd\u003e350 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow — 30 mJ\/cm² @ 95% UVT\u003c\/td\u003e\n      \u003ctd\u003e23 LPM\u003c\/td\u003e\n      \u003ctd\u003e57 LPM\u003c\/td\u003e\n      \u003ctd\u003e79 LPM\u003c\/td\u003e\n      \u003ctd\u003e151 LPM\u003c\/td\u003e\n      \u003ctd\u003e208 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow — 40 mJ\/cm² @ 95% UVT\u003c\/td\u003e\n      \u003ctd\u003e17 LPM\u003c\/td\u003e\n      \u003ctd\u003e45 LPM\u003c\/td\u003e\n      \u003ctd\u003e59 LPM\u003c\/td\u003e\n      \u003ctd\u003e120 LPM\u003c\/td\u003e\n      \u003ctd\u003e158 LPM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePort size\u003c\/td\u003e\n      \u003ctd\u003e¾\" MNPT\u003c\/td\u003e\n      \u003ctd\u003e1\" MNPT\u003c\/td\u003e\n      \u003ctd\u003e1\" MNPT\u003c\/td\u003e\n      \u003ctd\u003e1½\" MNPT\u003c\/td\u003e\n      \u003ctd\u003e2\" BSP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eChamber material\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e304 SS\u003c\/td\u003e\n      \u003ctd\u003e316L SS\u003c\/td\u003e\n      \u003ctd\u003e316 SS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of lamps\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLamp power\u003c\/td\u003e\n      \u003ctd\u003e22W\u003c\/td\u003e\n      \u003ctd\u003e50W\u003c\/td\u003e\n      \u003ctd\u003e42W\u003c\/td\u003e\n      \u003ctd\u003e101W\u003c\/td\u003e\n      \u003ctd\u003e130W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal power\u003c\/td\u003e\n      \u003ctd\u003e30W\u003c\/td\u003e\n      \u003ctd\u003e62W\u003c\/td\u003e\n      \u003ctd\u003e51W\u003c\/td\u003e\n      \u003ctd\u003e108W\u003c\/td\u003e\n      \u003ctd\u003e170W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLamp life\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs\u003c\/td\u003e\n      \u003ctd\u003e10,000 hrs\u003c\/td\u003e\n      \u003ctd\u003e9,000 hrs (1yr continuous)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupply voltage\u003c\/td\u003e\n      \u003ctd\u003e90–265V \/ 50–60Hz\u003c\/td\u003e\n      \u003ctd\u003e90–265V \/ 50–60Hz\u003c\/td\u003e\n      \u003ctd\u003e90–265V \/ 50–60Hz\u003c\/td\u003e\n      \u003ctd\u003e90–265V \/ 50–60Hz\u003c\/td\u003e\n      \u003ctd\u003e230–240V \/ 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating pressure\u003c\/td\u003e\n      \u003ctd\u003e69–860 kPa\u003c\/td\u003e\n      \u003ctd\u003e69–860 kPa\u003c\/td\u003e\n      \u003ctd\u003e69–860 kPa\u003c\/td\u003e\n      \u003ctd\u003e69–860 kPa\u003c\/td\u003e\n      \u003ctd\u003e0–860 kPa*\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWater temperature\u003c\/td\u003e\n      \u003ctd\u003e2–40°C\u003c\/td\u003e\n      \u003ctd\u003e2–40°C\u003c\/td\u003e\n      \u003ctd\u003e2–40°C\u003c\/td\u003e\n      \u003ctd\u003e2–40°C\u003c\/td\u003e\n      \u003ctd\u003e8–40°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eChamber dimensions\u003c\/td\u003e\n      \u003ctd\u003e6.4 x 54.2 cm\u003c\/td\u003e\n      \u003ctd\u003e6.4 x 101.6 cm\u003c\/td\u003e\n      \u003ctd\u003e8.9 x 91.7 cm\u003c\/td\u003e\n      \u003ctd\u003e8.9 x 103.4 cm\u003c\/td\u003e\n      \u003ctd\u003e895 x 750 x 190 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReplacement lamp\u003c\/td\u003e\n      \u003ctd\u003eUV24LAMP\u003c\/td\u003e\n      \u003ctd\u003eUV57LAMP\u003c\/td\u003e\n      \u003ctd\u003eUV80LAMP\u003c\/td\u003e\n      \u003ctd\u003eUV151LAMP\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReplacement sleeve\u003c\/td\u003e\n      \u003ctd\u003eUV24SLEEVE\u003c\/td\u003e\n      \u003ctd\u003eUV57SLEEVE\u003c\/td\u003e\n      \u003ctd\u003eUV80SLEEVE\u003c\/td\u003e\n      \u003ctd\u003eUV151SLEEVE\u003c\/td\u003e\n      \u003ctd\u003e—\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWaterMark\u003c\/td\u003e\n      \u003ctd\u003eWM 3497 Lic. 023355\u003c\/td\u003e\n      \u003ctd\u003eWM 3497 Lic. 023355\u003c\/td\u003e\n      \u003ctd\u003eWM 3497 Lic. 023355\u003c\/td\u003e\n      \u003ctd\u003eWM 3497 Lic. 023355\u003c\/td\u003e\n      \u003ctd\u003eNot stated on brochure\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003e*UV250: Installation prior to the pump is not recommended.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWater Quality Requirements\u003c\/h2\u003e\n\n\u003cp\u003eFor reliable UV performance, incoming water must meet the following limits. If these are exceeded, pre-treatment is required.\u003c\/p\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eMaximum\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHardness\u003c\/td\u003e\n      \u003ctd\u003e120 mg\/L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIron (Fe)\u003c\/td\u003e\n      \u003ctd\u003e0.3 mg\/L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManganese (Mn)\u003c\/td\u003e\n      \u003ctd\u003e0.05 mg\/L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTannins\u003c\/td\u003e\n      \u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTurbidity\u003c\/td\u003e\n      \u003ctd\u003e1 NTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV transmittance (UVT)\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt;75%\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eService Intervals\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel\u003c\/th\u003e\n      \u003cth\u003eComponent\u003c\/th\u003e\n      \u003cth\u003eInterval\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV24 \/ UV57 \/ UV80\u003c\/td\u003e\n      \u003ctd\u003eUV lamp\u003c\/td\u003e\n      \u003ctd\u003e9,000 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV151\u003c\/td\u003e\n      \u003ctd\u003eUV lamp\u003c\/td\u003e\n      \u003ctd\u003e10,000 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV250\u003c\/td\u003e\n      \u003ctd\u003eUV lamp\u003c\/td\u003e\n      \u003ctd\u003eAnnually (9,000 hours \/ 1 year continuous)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV250\u003c\/td\u003e\n      \u003ctd\u003eQuartz sleeve\u003c\/td\u003e\n      \u003ctd\u003eClean or replace every 3–6 months, subject to water quality\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel\u003c\/th\u003e\n      \u003cth\u003eIncludes\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV24 \/ UV57 \/ UV80 \/ UV151\u003c\/td\u003e\n      \u003ctd\u003eUV chamber, controller, mounting brackets, power lead with standard NZ 10A plug (AS\/NZS 3112)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUV250\u003c\/td\u003e\n      \u003ctd\u003eUV chamber, power supply enclosure, 1m interconnecting cable (chamber to power supply), 1.7m power lead with 3-pin plug, stainless steel mounting brackets\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e10 years — stainless steel chamber\u003c\/li\u003e\n  \u003cli\u003e3 years — electronics\u003c\/li\u003e\n  \u003cli\u003e12 months — UV lamps and quartz sleeves\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhich model suits my home?\u003c\/h3\u003e\n\u003cp\u003eMatch the model to your peak flow demand. UV24 suits single-tap or low-flow setups. UV57 suits small households. UV80 suits medium-sized homes. UV151 suits large homes or high-demand properties. UV250 suits high-flow applications. If you're not sure, get in touch and we'll help you size it correctly.\u003c\/p\u003e\n\n\u003ch3\u003eDo these units include filter housings or cartridges?\u003c\/h3\u003e\n\u003cp\u003eNo. These are standalone UV disinfection units only. Pre-filtration must be installed upstream — at minimum 20 micron cartridge filtration, and 1 micron where Giardia or Cryptosporidium are a concern. Get in touch and we'll recommend the right combination for your supply.\u003c\/p\u003e\n\n\u003ch3\u003eDo I need a plumber to install it?\u003c\/h3\u003e\n\u003cp\u003eFor most customers, yes — a licensed plumber is the safest path and protects your warranty on the plumbing side. These units arrive assembled, plug into a standard power outlet, and suit horizontal or vertical installation. If you're confident with household plumbing, the installation itself is straightforward. If you're not sure, get in touch and we'll help you decide.\u003c\/p\u003e\n\n\u003ch3\u003eWhat connection fittings will I need?\u003c\/h3\u003e\n\u003cp\u003eUV24, UV57, UV80, and UV151 have NPT connections. NPT is not the NZ standard — your plumber will need BSP-to-NPT adaptors, available from most plumbing merchants. The UV250 has 2\" BSP connections, which are standard.\u003c\/p\u003e\n\n\u003ch3\u003eHow often do I replace the lamp?\u003c\/h3\u003e\n\u003cp\u003eUV24, UV57, UV80: every 9,000 hours. UV151: every 10,000 hours. UV250: annually (9,000 hours \/ 1 year continuous use). The UV24–UV151 controllers include an advance lamp change reminder. The UV250 alarms when the lamp fails — replace it annually as a matter of routine rather than waiting for the alarm.\u003c\/p\u003e\n\n\u003ch3\u003eIs the UV250 compatible with a standard NZ power outlet?\u003c\/h3\u003e\n\u003cp\u003eThe UV250 operates on 230–240V\/50Hz only and comes with a 1.7m power lead with a standard 3-pin plug. Confirm your installation is compatible before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCan the unit be installed horizontally or vertically?\u003c\/h3\u003e\n\u003cp\u003eYes. Both orientations are supported. If installed horizontally, the outlet should point upwards. If installed vertically, the outlet should point horizontally. Mounting brackets are included.\u003c\/p\u003e\n\n\u003ch3\u003eIs UV suitable for rainwater or bore water?\u003c\/h3\u003e\n\u003cp\u003eYes, subject to water quality. Incoming water must meet the quality parameters listed above. Bore water quality varies significantly — we recommend testing before installing. Get in touch and we'll help you choose the right configuration for your supply.\u003c\/p\u003e\n\n\u003ch3\u003eDoes UV treatment affect the taste or smell of my water?\u003c\/h3\u003e\n\u003cp\u003eNo. UV adds no chemicals and leaves no residuals. Taste, smell, colour, and chemistry are unchanged.\u003c\/p\u003e\n\n\u003ch3\u003eWhat warranty comes with these units?\u003c\/h3\u003e\n\u003cp\u003e10 years on the stainless steel chamber, 3 years on electronics, and 12 months on UV lamps and quartz sleeves.\u003c\/p\u003e","brand":"Davey","offers":[{"title":"UV24","offer_id":45202683625516,"sku":"UV24","price":795.8,"currency_code":"NZD","in_stock":true},{"title":"UV57","offer_id":45202683658284,"sku":"UV57","price":1616.9,"currency_code":"NZD","in_stock":true},{"title":"UV80","offer_id":45202683691052,"sku":"UV80","price":1992.95,"currency_code":"NZD","in_stock":true},{"title":"UV151","offer_id":45202683723820,"sku":"UV151","price":2957.8,"currency_code":"NZD","in_stock":true},{"title":"UV250","offer_id":45527114481708,"sku":"UV250","price":5171.55,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/5966\/6732\/files\/microlene-UV24-1-1024x777_png.webp?v=1747561753","url":"https:\/\/www.filtrationstation.co.nz\/products\/davey-microlene-uv-water-disinfection-system","provider":"Filtration Station NZ","version":"1.0","type":"link"}